GEFRAN controllers are configurable microprocessor panel instruments that precisely control variables such as temperature, pressure, force, humidity, position, etc., with programmable alarms and optional communication interface. Accessories for controllers and programmers; Configure. Double loop PID Controller, 1/16 DIN.
• Logic inputs Ri = 4,7KΩ (24V, 5mA) or no-voltage contact SERVICE: GEFRAN has a service department. The warranty excludes defects caused by any Serial interface (optional) RS485, isolated use not conforming to these instructions. • 3 • DESCRIPTION OF FACEPLATE Function indicators Indication of output states Indicates modes of operation OUT 1 (AL1); OUT 2 (Main); OUT 3 (HB); OUT 4 (HB) MAN/AUTO = OFF (automatic control) ON (manual control) PV Display: Indication of process variable Error Indication: LO, HI, Sbr, Err SETPONT1/2 = OFF (IN1 = OFF - local Setpoint 1) LO= the value of process variable is.
Microprocessor controller, 48x96 (1/8 DIN) format for model 1000 and 96x96 (1/4 DIN) format for models 1001 and 1101 manufactured using SMT. The 1000 family of controllers provide a complete operator interface, with a Lexan membrane faceplate to give IP54 frontal protection that has 3 keys, two green LED displays with 3 (1000) or 4 (1001 and 1101) digits, and red LED indicators for the 3 alarm relay outputs and a green LED for the main control output. The main input for the control variable is universal and provides the possibility of connecting different types of signal: • Thermocouples of types J, K, N, S, R, T • Resistance thermometer Pt100 (3-wire) • Linear inputs: 0-50mV, 10-50mV keyboard definable 2-10V, 0-10V, 0-20mA, 4-20mA with an external shunt. An auxiliary analogue input is available for a current transformer input. The instrument has a double control output that is both relay (5A, 250Vac at cos φ =1) and static (24Vdc, max.20mA) and up to a maximum of 3 alarm relay outputs (3A, 250Vac). Alternatively, the control output can be analogue (0-20mA, 4-20mA or 0-10V, 2-10V). The optional communications port can be current loop, or RS485 with GEFRAN (Cencal) protocol with a maximum speed of 9600 baud (RS485).
About ModelSim Mentor Graphics was the first to combine single kernel simulator (SKS) technology with a unified debug environment for Verilog, VHDL, and SystemC. Modelsim student edition.
The programming of the instrument is simplified by the grouping of the parameters into function blocks. Access to the configuration parameters is protected by a hardware jumper and different values of a protection code can be used to restrict the number of parameters that can be displayed and modified by the user.